EECO Valve Troubleshooting Kit for UV-5AT(C) & UV-5BT(C). Also available for UV-4R and UV-7B(C) Control Valves.
This kit provides parts commonly required during control valve service
Contains: Valve Catalog, Troubleshooting Guide, USB Flash Drive, Combo Wrench, 110vac Coil (Black Wire), 220vac Coil (Black Wire), Dynamic Seal Kit, and Solenoid Kit

This tool is used to adjust EECO Control Valves
Contains: Combination Adjusting Wrench

This tool is used to adjust EECO Control Valves
Contains: Z Shaped Adjusting Wrench

This kit provides all of the tools to adjust a UV-5A, T, or TC Valve.
Contains: Trouble Shooting Guide, Combination Valve Adjusting Wrench, USB Flash Drive which includes UV-5AT Valve Adjustment Video

Cylinder Lifting Clamps (CLC) are designed to lift and hold hydraulic jack cylinders safely during construction. Constructed of formed steel bar for light weight and easy handling. These clamps are equipped with shackles for lifting and tensioning bolts for applying pressure around cylinder pipe.

Download Files: 

Piston Clamp / Wrenches are designed to safely lift, hold, and tighten pistons during construction. The welded steel construction with replaceable tension pads and tensioning bolts for applying equal pressure around piston ensures higher griping force than wood clamps. Each clamp has a maximum rated load of 1950 lbs.
Model PCW-24 is designed for lifting from the handles. The handles on this model are not removable.
Models PCW-47 and PCW-712 have been designed for lifting from shackles that are supplied with the units. These models are equipped with removable handles for a more compact design during storage.
Custom sizes are available. Contact EECO for more details.
Note: To ensure safe lifting, holding and tightening, the piston and tension pads must be clean, dry and free of oil and grease. Also Piston Clamp / Wrench must be properly tightened around the piston.
(DURING LIFTING DO NOT ACCELERATE OR STOP QUICKLY)

PVC Lifting Clamps are designed to lift and hold flush joint PVC pipe safely. Constructed of formed and welded 1/4" steel plate for light weight and easy handling these clamps are equipped with two holding tabs and shackles for lifting. A tee bolt tensioner is used to apply pressure around PVC pipe with cupped set screws for gripping. The maximum rated load for the PVC Lifting Clamps is 3000 lbs.
Note: To ensure safe lifting and holding, the clamp must be properly tightened around PVC pipe by adjusting the cupped set screws.

The PeViCol PVC Cement was specially designed for gluing PVC pipe. This non-flammable cement does not require a primer. The low odor and low emissions allows to be used indoors with minimal ventilation. The cement can be used in a temperature range from 32º - 176º F (0º - 80º C). PeViCol PVC Cement, a NordColl product, is not classified as an environmental toxin and the solvents in solutions are biologically degradable.

EECOLube: The EECOLube is a performance improving friction modifier oil additive formulated to reduce "Stick Slip", rough starts & stops and prevent noise in hydraulic elevator systems. EECOLube is compatible with petroleum or biodegradable oils. EECO recommends using 1 bottle (quart) per 60 gallons of oil.

The Adjustable Spanner Wrench can be used on the Telescopic Jack’s Head Flanges. The wrench’s drop forged jaws are 3/8” thick with 11 adjustable positions for a capacity from 4-3/4” to 12-3/4” outside diameter and the handle is 1” in diameter and 24”’ long.

This Evacuation Pump is used to drain residual oil remaining in the space between the cylinder(s) and the piston(s) while disassembling the Telescopic Jacks to service the internal head(s). The pump has a 1/4" shaft to fit a drill motor (minimum speed of 800 rpm) and is supplied with 25’‐0” of flexible tubing. Longer tubing lengths are available. The pump has a maximum head of 55’‐0”, 1.8 gpm based on 1200 rpm, and operating temperature of 1200 F. Do not pump gasoline or other flammable fluids.

This Piston Repair Kit (PRK-01) is designed to repair damaged piston with deep scratches or pits that cause excessive weeping of oil through the seals. The two part metal filled epoxy is ideal for filling in deep scratches and pits that are too deep to be removal with just light sanding. Using this kit, once properly applied, can prolong a damaged piston and seal life.
This kit is not designed to repair pistons that are undersized due to excess of sanding.
The Kit includes the following:
Piston Repair Epoxy Kit Hardener
Resin
Wooden Paddles Epoxy MSDS
Instruction Sheet Degreaser
80 Grit Emery Cloth 400 Grit Emery Cloth Putty Knife
Mixing Cup

Telescopic Lifting Clamp Assemblies (TLC) are specifically designed to lift EECO Telescopic Jacks, and are to be mounted on the cylinder under the lower head. These clamps are designed to lift and hold hydraulic jack cylinders safely during construction. Constructed of formed steel bar for light weight and easy handling. These clamps are equipped with shackles for lifting and tensioning bolts for applying pressure around cylinder pipe. The maximum rated load for the Telescopic Cylinder Lifting Clamp is 2,000 lbs.

Also available for UV-4R and UV-5 Series Control Valves.
This kit provides parts commonly required during control valve service
Contains: Valve Catalog, Troubleshooting Guide, USB Flash Drive, Combo Wrench, 110vac Coil (Black Wire), 230vac Coil (Black Wire), Dynamic Seal Kit, and Solenoid Kit.

Also available for UV-5 Series and UV-7B(C) Control Valves
This kit provides parts commonly required during control valve service Contains: Valve Catalog, Troubleshooting Guide, USB Flash Drive, Combo Wrench, 110vac Coil (Black Wire), 24vdc Coil (Black Wire), Dynamic Seal Kit, and Solenoid Kit.

This Multi-Piece Piston Kit (MPK) is required for every joint that EECO supplies. The kit is designed
to fill in the hairline gap that may occur after tightening the piston sections together. The hairline
gap makes the piston weep oil which may look like the piston is filling with oil, although the piston
joints are designed with o-ring seals and solid coupling or baffle plates to avoid oil from filling the inside of the piston.

This kit includes the following:
Instruction Sheet
Putty Knife
Marine-Tex Epoxy MSDS
Mixing Cup
Degreaser
Emery Cloth
Marine-Tex Epoxy Compound
Non-Hardening Gasket Sealant #2 (Thread sealant)

The LS-1B Elevator Limit Switch is designed primarily for use in elevator hoistways as Access, Slow Down, Normal, and Final Limits. The light weight durable construction of the LS-1B switch results in a reduced noise level and is designed for extended reliability.

Download Files: 

Mounted directly onto the main jack connection, the Pipe Rupture Valve (PRV) is simple to adjust and extremely reliable in operation. Should an overspeed of the elevator occur, the damped closing of the PRV ensures a quick but smooth slowdown of the car. Slowing to a stop is standard; slowing to a down creep speed is optional.
Grooved or NPT straight through line connections enable the customer to attach the PRV to the existing cylinder and pressure line connections in the shortest possible installation time.

The Permanent Magnet Switch (MV) is designed primarily for applications requiring trouble free service. This switch provides a cost effective and simple solution for environments where mechanical contact between the actuating vane and switch is not desired.
Switches are available in two configurations, SPDT with one normally open & one normally closed contacts and DPDT with two normally open & two normally closed contacts.

Download Files: 

The Permanent Magnet Inductor Switch (LDS-3004A) is intended for use on hydraulic and electric elevators with speeds up to 400 feet per minute and one floor run control. The LDS-3004A is made to interface with either relay logic, micro-processor or programmable logic controllers. The horseshoe shaped inductor switch provides noiseless sensing of slowdown and landing positions of the elevator.
The LDS-3004A Inductor Switch features solid metal construction and uses both a normally open and a normally closed contact reed switch as standard.

Download Files: 

The Isolation Couplings (ISO) are available in three sizes both grooved and threaded. These couplings are designed for electrical isolation with a Dielectric Strength of 42 kV and will also help in the reduction of vibration and noise from being transmitted to the cab. The maximum operating temperature for these Isolation Couplings is 225º F (107º C).

All Isolation Couplings are designed to meet or exceed ASME A17.1/CSA B44.

The Shut Off Valve (SOV) is used to isolate one section of the system from another. All Shut Off Valves are constructed of ductile iron bodies and use a stainless steel ball. A locking device is standard on all sizes.

(includes Ball Valve & Handles}

The Muffler (MU) provides superior noise suppression for most standard
power unit installations. The unit working pressure is 1200 psi and it is 11-3/4” long.
Unit diameter for 2” size is 6-5/8” and 8-5/8” for other sizes.

Download Files: 

The EECO Hydraulic Dampener (EHDN) is extremely effective in suppressing the sound and pulsation present in hydraulic elevator systems. The EHDN has a minimum burst pressure of 6000 psi with an ASME A17.1/CSA B44 allowable working pressure of 1200 psi. Unit diameter is 8-5/8” and the length for 2", 2.5", and 3" is 11.75". The 4" outlet unit has a diameter of 10.75" and a length of 13.75".

Download Files: 